P/N: 575-01110-00
Precise setting of rotation speed and heating bath temperature on the digital touch display or – for quick access during an active process – directly via the knobs on the operating panel.
P/N: 575-01100-00
Precise setting of rotation speed and heating bath temperature on the digital touch display or – for quick access during an active process – directly via the knobs on the operating panel.
P/N: 575-01310-00
Precise setting of rotation speed and heating bath temperature on the digital touch display or – for quick access during an active process – directly via the knobs on the operating panel.
P/N: 575-01300-00
Precise setting of rotation speed and heating bath temperature on the digital touch display or – for quick access during an active process – directly via the knobs on the operating panel.
P/N: 575-01315-00
Precise setting of rotation speed and heating bath temperature on the digital touch display or – for quick access during an active process – directly via the knobs on the operating panel.
P/N: 575-01305-00
Precise setting of rotation speed and heating bath temperature on the digital touch display or – for quick access during an active process – directly via the knobs on the operating panel.
P/N: 575-01510-00
Precise setting of rotation speed and heating bath temperature on the digital touch display or – for quick access during an active process – directly via the knobs on the operating panel.
P/N: 575-01500-00
Precise setting of rotation speed and heating bath temperature on the digital touch display or – for quick access during an active process – directly via the knobs on the operating panel.
P/N: 575-01610-00
Precise setting of rotation speed and heating bath temperature on the digital touch display or – for quick access during an active process – directly via the knobs on the operating panel.
P/N: 575-01600-00
Precise setting of rotation speed and heating bath temperature on the digital touch display or – for quick access during an active process – directly via the knobs on the operating panel.
P/N: 576-01110-00
Precise setting of rotation speed and heating bath temperature on the digital touch display or – for quick access during an active process – directly via the knobs on the operating panel.
P/N: 576-01100-00
Precise setting of rotation speed and heating bath temperature on the digital touch display or – for quick access during an active process – directly via the knobs on the operating panel.
P/N: 576-01310-00
Precise setting of rotation speed and heating bath temperature on the digital touch display or – for quick access during an active process – directly via the knobs on the operating panel.
P/N: 576-01300-00
Precise setting of rotation speed and heating bath temperature on the digital touch display or – for quick access during an active process – directly via the knobs on the operating panel.
P/N: 576-01315-00
Precise setting of rotation speed and heating bath temperature on the digital touch display or – for quick access during an active process – directly via the knobs on the operating panel.
P/N: 576-01305-00
Precise setting of rotation speed and heating bath temperature on the digital touch display or – for quick access during an active process – directly via the knobs on the operating panel.
P/N: 576-01510-00
Precise setting of rotation speed and heating bath temperature on the digital touch display or – for quick access during an active process – directly via the knobs on the operating panel.
P/N: 576-01500-00
Precise setting of rotation speed and heating bath temperature on the digital touch display or – for quick access during an active process – directly via the knobs on the operating panel.
P/N: 576-01610-00
Precise setting of rotation speed and heating bath temperature on the digital touch display or – for quick access during an active process – directly via the knobs on the operating panel.
P/N: 576-01600-00
Precise setting of rotation speed and heating bath temperature on the digital touch display or – for quick access during an active process – directly via the knobs on the operating panel.
Precise setting of rotation speed and heating bath temperature on the digital touch display or – for quick access during an active process – directly via the knobs on the operating panel.
Asansör | Hand lift or Motor lift |
---|---|
Rotasyon hız derecesi | 10 - 280 rpm |
Rotasyon hız göstergesi | 7" LCD color graphic display |
Isıtma kapasitesi | 1.300 W |
Aşırı ısınma korumalı banyo | cut-off at 5 °C over set temperature via separate PT 1000 |
Banyo sıcaklık ayarı | 7" LCD color graphic display |
Isıtma banyosu sıcaklık kontrol | electronic / digital |
Mak. ölçü evaporasyon balonu | 5 l |
Entegre vakum kontrol | - |
Zamanlayıcı | Yes |
Integrated Hei-CHILL controller | - |
Dynamic AUTOaccurate vakum program AUTOaccurate sensör gerektirir | - |
Programlanabilir ramplar | Yes |
Yoğuşmalı yüzey | 1.400 cm² |
Yoğuşmalı yüzey XL kondenser | 2.200 cm² |
AWARD-WINNING EVAPORATION SYSTEMS – Rotary evaporators | İndir |
At a glance-Hei-VAP 2019_EN.pdf | İndir |
Hei-VAP-Certificate-for-continuous-operation.pdf | İndir |
CE-Rotationsverdampfer-Rotary-Evaporators.pdf | İndir |
Chiller Selection Matrix | İndir |
Vacuum Configurator Matrix | İndir |
Hei-VOLUME Distimatic - The clever way of continuous evaporation | İndir |
NRTL-Certificate-Rotary-Evaporators.pdf | İndir |
Operation-Manual-Rotary Evaporator-Hei-VAP-Expert-Ultimate-Control.pdf | İndir |
A spider NS 24/29 can be used on an evaporator with NS 24/40. There is no adapter or other accessories needed.
To check the tightness of the cooling circuit, please proceed as follows ...
Yes, the rotary evaporator can be flooded with inertgas via the ventilation valve of the vacuum box ...