P/N: 523-52013-00
Accurate dosing is particularly important in the pharmaceutical, cosmetic or food sector. Comprehensible process conditions are a prerequisite for the safe conveyance of sensitive media. This is ensured by a control accuracy of ±1% and precise speed adjustment (5 — 120 rpm).
In addition, an optional foot switch allows the pump to be operated in closed exhaust hoods. The parameters - speed, direction of rotation and on/off function - can be controlled externally either through the analog or digital interface.
In this model, you can choose between a single-channel or multichannel pump head. Flow rates vary depending on the pump head: the single-channel head has a flow rate of 0.38 — 813 ml/min; for the multi-channel head 0.005 — 364 ml/min. Depending on the focus of the process, the following parameters can be set on the device: Speed, tubing diameter, flow rate display, metering volume, interval dosing and break times. The pump can be calibrated for optimum dosing results.
P/N: 523-52010-00
Accurate dosing is particularly important in the pharmaceutical, cosmetic or food sector. Comprehensible process conditions are a prerequisite for the safe conveyance of sensitive media. This is ensured by a control accuracy of ±1% and precise speed adjustment (5 — 120 rpm).
In addition, an optional foot switch allows the pump to be operated in closed exhaust hoods. The parameters - speed, direction of rotation and on/off function - can be controlled externally either through the analog or digital interface.
In this model, you can choose between a single-channel or multichannel pump head. Flow rates vary depending on the pump head: the single-channel head has a flow rate of 0.38 — 813 ml/min; for the multi-channel head 0.005 — 364 ml/min. Depending on the focus of the process, the following parameters can be set on the device: Speed, tubing diameter, flow rate display, metering volume, interval dosing and break times. The pump can be calibrated for optimum dosing results.
Speed range | 5 - 120 rpm |
---|---|
Control accuracy motor | ±0.5 % |
Select direction of rotation | CW / CCW |
Flow rates single-channel pumps | 0.38 – 813 ml/min |
Flow rates multi-channel pumps | 0.005 – 364 ml/min |
Flow rate accuracy (water without counter pressure) | ±1 % |
Interval dosing | 0.001 – 9,999 ml in breaks 0.1 sec -750 h |
Volume dosing | 0.001 – 9,999 ml |
Analog interface | for speed 0 - 10 V / 4 - 20 mA direction of rotation start/stop |
Digital Interface | RS 232 |
Protection class IEC 60529 | IP 55 |
ROBUST ACROBATS – Shakers & Peristaltic Pumps | Download |
Hei-FLOW at a glance | Download |
Hei-FLOW-Certificate-for-continuous-operation.pdf | Download |
Tubing-sizes-and-flow-rates.pdf | Download |
CE-Peristaltikpumpe-Peristaltic-pump.pdf | Download |
Operation Manual Hei-FLOW Core-Exper-Ultimate | Download |
When used correctly, no air bubbles emerge in the tube. The end of the tube must be deep enough in the container, from which the substance should be pumped.
With our Hei-FLOW peristaltic pumps, the high precision achieves minimum flow rate of only 0.005 ml/min.